Faster, cleaner, and more durable than cement
Reduced Job
CostReducing Environmental
FootprintFacilitating Rapid
Compliance
StaticFlo delivers an epoxy barrier system engineered to solve complex well remediation challenges.
Our hydrophobic and chemically resistant epoxy bonds to steel, cement, and formation surfaces.

Epoxy components are precisely metered and blended in real time, eliminating the issues associated with batch mixing, excessive exothermic reactions, and extended cure times.
The result is a controlled, efficient application process that allows operators to test and validate barrier integrity in hours (not days) while minimizing cleanup, waste, and operational downtime.
Our pumping units eliminate all the traditional issues with using epoxy products and provide operators with a better barrier material quickly and efficiently.
Faster Time to Results
Restore well integrity and resume operations in hours—not days.
Reduced Job
Cost
Fewer personnel, less equipment, less NPT, and lower chemical waste means significantly lower costs.
Reduced Risk of Job Failure
With precise metering, temperature control, and no batch guesswork, our epoxy does what is required when it’s needed.
Improved Safety and Environmental Profile
Closed-loop cleaning, no on-site solvent handling, and reduced personnel all contribute to a safer, more compliant operation.
Scalable for Multiple Applications
From onshore production wells to injection and storage wells and even deepwater, StaticFlo is ready for both niche jobs and scaled rollouts.
And geek out like we do.
System Output
3 GPM to 53 GPM
6000-1900 PSI
Crew Requirements
Two-person operation
Mix Ratio
Ability to pump variable pre-determined ratios of epoxy to catalyst
Cure Time
Adjustable; standard cure within: 4-8 hours
Pump System
Self-contained with HMI control panel, data loggers, Coriolis flow meters
Compatibility
Bonds to cement, steel, and other cured epoxy, no cold seams
Temperature Range
Tested from 70°F–200°F
Viscosity Mixed @ 70 F
~375 cP
Density
Density can be adjusted from 9.2-13ppg


18,500 psi Ultimate Compressive Strength
3,400 psi Tensile Strength
Proven Penetration into Micro-Annuli
StaticFlo’s low-solids formulation can be “squeezed” into spaces where cement fails.
2,100 psi Shear Bond to Steel
0% Weight Gain in Acid or Saltwater after 7-week hot-wet aging @ 162°F